FN5-12 ụdị ime ụlọ AC elu voltaji ibu brek mgba ọkụ (nke a na-ezo aka dị ka ibu nkwụsịtụ mgba ọkụ) apụl ka AC 50Hz 12kV netwọk, n'ihi na-agbasa ibu ugbu a na-emechi obere sekit ugbu a. Mgbanwe nkwụsịtụ na fuse nwere ike ịbelata sekit dị mkpụmkpụ maka nchebe mgba ọkụ.
Enwere ike iji mgba ọkụ nbibi ibu na ụdị ntuziaka arụ ọrụ ụdị CS6-1, na ngwaahịa a pụrụ iche na-eji CS akwụkwọ ntuziaka na-arụ ọrụ.
Ngwa
FN5-12 ụdị ime ụlọ AC elu voltaji ibu nkwụsịtụ mgba ọkụ (nke a na-ezo aka dị ka ibu nkwụsị ọkụ ọkụ) na-emetụta AC 50Hz 12kV netwọk, n'ihi na-agbasa ibu ugbu a na-emechi obere sekit ugbu a. Mgbanwe nkwụsịtụ na fuse nwere ike ịbelata sekit dị mkpụmkpụ maka nchebe mgba ọkụ.
Enwere ike iji mgba ọkụ nbibi ibu na ụdị ntuziaka arụ ọrụ CS6-1, ngwaahịa a na-eji CS pụrụ icheọnụntuziaka arụ ọrụ usoro.
Ụdị na Pụtara
Jiri gburugburu ebe obibi
a. Elu
b. Ambient ikukurmFre: -25 ~ + 40 ° C, (motorized arụ ọrụ usoro〉-5°C);
c. Iru mmiri dị ala: nkezi kwa ụbọchị
d. Ikuku ikuku na-enweghị mmetọ doro anya, dị ka gas na-emebi emebi ma ọ bụ ọkụ ọkụ, uzuoku mmiri, wdg.
e. Na-enweghị mmaji siri ike ọzọ.
Data teknụzụ
4.1 Ibu ihe ngbanwe ngbanwe teknụzụ dị na tebụl 1
Aha | Nkeji | Uru |
Egosiri voltaji | kV | 12 |
Voltaji arụ ọrụ kacha | kV | 12 |
Ugboro ugboro | Hz | 5. |
Enyere ugbu a | A | 400 630 |
Obere oge na-anagide ugbu a (ụgwọ nkwụsi ike ugbu a) | kA/S | 12.5/4 20/2 |
Ogo kacha elu na-anagide ugbu a (nkwụsi ike ugbu a) | ka | 31.5 50 |
Enyere aka mechiri emechi oge na-agbaji | A | 400 630 |
Enyere ikike ibu ihe na-agbaji ugbu a | A. | 400 630 |
5% kwadoro na-ebunye ike na-agbaji ugbu a | A | 20 31.5 |
Enyere ogo ọcha na-agbaji ugbu a | A | 10 |
Enyere ogo ọ nweghị ihe ngbanwe na-agbaji ugbu a | 1250kVA enweghị ibu ugbu a nke transformer | |
Enyere obere sekit mmechi ugbu a | ka | 31.5 50 |
Bunye oge nbibi ugbu a | Ibu ibu/oge | 100%/20 30%/75 60%/35 5%/80 |
1min ugboro ike w;nstanna voltaji (RMS), frac-to-phase / isoktmg mgbaji | kV | 42/48 |
Ugboro ike v^tnstand voltaji n'etiti ikewa mgbaji | kV | 53 |
Ọkụ ọkụ na-anagide voltaji gaa n'ala(elu), nkebi-na-adọ/napụrụ mgbaji | kV | 75/85 |
Ọkụ ọrụ imeghe/emechi | Nm(N) | 90 (80) 100 (200) |
Mara: FN5-12D gbadoro ụkwụ n'akụkụ nke ngbanwe ibu na obere okirikiri na-eme ikike ugbu a.
4.2 Fuse teknuzu oke table2
Nlereanya | Ogo nke voltaji KV | Fuse Enyere ugbu a A | Enyere nbibi ugbu a KA | Ogo nke fuse- elementrị ugbu a |
RN3 | 12 | 50 | 12.5 | 2, 3, 5, 7.5, 12, 15,20,30, 40, 50 |
75 | 75 | |||
100 | 100 | |||
200 | 150 200 | |||
SDL*J | 12 | 40 | 50 | 6.3, 10, 16, 20, 25,31.5,40 |
SFL*J | 12 | 100 | 50, 63, 71, 80, 100 | |
SKL*J | 12 | 126 | 125 |
Ọdịdị na nwụnye akụkụ (mm)
Foto 1 FN5-12
1. Framework 2. Post insulator 3. Na-ebu wiring osisi 4. Agụba 5. Arc extinguisher
6. Torsional spring and his pin bearing 7. Guide bar 8. Wiring board 9. Lever
10. Ibu ngbanwe na-ebugharị na-ebugharị 11. Usoro nchaji mmiri 12. Usoro ọrụ
Foto 2 FN5-12D
1. Framework 2. Ụwa blad , 3. 7 , Rth mgba ọkụ na-akpụ akpụ 4. Post insulator
5. Igwe na-akpụ akpụ n'ụwa 6. Bịlụ wiring osisi 7. Agụba 8. Arc extinguisher
9. Sere mmiri na+ntụtụ nke mmiri 10. Nduzi mmanya 11. Wiring board 12. Lever
13.Load mgba ọkụ na-ebu 14. Ibu ọkụ mgba ọkụ mmiri nchaji usoro
15. Ụwa swl,h ^mgbanaka chaja usoro 16. Ibu ọrụ mgba ọkụ arụ ọrụ
17. Er rth vi ch sistemu arụ ọrụ 18. Interlock usoro
Fig.3FN5-12R(S)
1. FN5-12R ibu sv 2. Bering fuse wiring board 3. Fuse link 4. Fuse wiring board
5. Fuse base
Fig.4FN5-12DR
Nhazi usoroCS6-1 csn | Ụdị Fuse L | H | h | |
SDL*J,SFL*J,SKL*J | 935 | 530 | ||
735 RN3-10 |
| 990 | 585 | |
5=75 | 1040 | 635 |
1. FN5-12D ibu s.'
5. Fuse base
Fig.4FN5-12R(S)
1. FN5-12 ibu swiiti,c:i 2. Bering,se wiring osisi 3. Fuse 4. Fọlụ wiring osisi 5. Fuse base
Foto 6 FN5-12DR(S)
1. FN5-12D mgba ọkụ 2. Bering fuse wiring osisi 3. Fuse 4. Fuse wiring osisi
5. Fusabuo6. Usoro njikọ
Foto 7 FN5-12R (D) L
1. N'okpuru etiti 2. Insulator 3. Fuse 4. Ngwaọrụ Tripper 5. Kọntaktị na-ebugharị 6. Arc extinguisher
7. Ogwe ntụzịaka 8. kọntaktị static 9. Usoro mmeghe / mmechi 10. Ngwa njikọ
11. Ibu ọrụ mgba ọkụ na-arụ ọrụ 12. Ụwa mgba ọkụ